Riccar Vacuum No Suction? Here’s How To Fix It In 5 Easy Steps!

Are you frustrated with your Riccar vacuum’s lack of suction power? You’re not alone!

Don't Miss Out! ⏳ Click For Amazon's Exclusive Vacuum Deals!

It can be incredibly frustrating when your trusty cleaning tool suddenly stops working as it should. But fear not, because we’ve got the solution to this all-too-common problem 🙂

In this article, we’ll share our expertise on how to troubleshoot and fix a Riccar vacuum that has lost its suction.

Whether you’re a seasoned DIYer or new to the world of home maintenance, we’ve got tips and tricks that will help you get your vacuum back up and running in no time.

We understand how important it is to have a dependable cleaning tool at hand, especially if you have pets or young children.

So grab your toolbox (or just some basic household items) and let’s get started on fixing that pesky suction issue once and for all.

Common Reasons for Riccar Vacuum No Suction

Clogged or Dirty Filters

One of the primary culprits behind reduced suction power is dirty filters. Your Riccar vacuum has three types of filters: air filter, exhaust filter and motor filter.

Air Filter

The air filter removes dust and other particles from incoming air before it reaches the motor. Over time, this filter can become clogged with dirt and debris.

Solution: remove the air filter according to your machine’s manual instructions. Replace or clean it as necessary (depending on whether it is washable or disposable).

Exhaust Filter

The exhaust filter catches any leftover particles that were not trapped by the air filter as they exit via the outgoing airflow channel at rear of machine Some models have an external unit tis easily accessible while others may require removal of back cover..

Solution: refer to manufacturer’s manual instructions regarding removing cover/ side panels /filter assembly.Positioning new replacement requires proper alignment otherwise damage may result upon controlling/screwing components in place)..

Motor Filter

Located next to main fan within motor housing inside body ,motor filters protects against accumulation/damage by stray hairs or fine particles .

Solution: Remove Motor Housing screws according to manufacturer’s recommendation depending on model . Take out old Motor Filter & replace with new one.Make sure Installing all parts properly before re-assembling Machine…

Hose Blockage or Damage

Blockages in the vacuum hose can also lead to poor suction power. Debris, hair particles and other obstructions can accumulate over time and clog up the hose.

Solution: Detach both ends of your Riccar vacuum’s hose from machine body ,inspect for cracks/cuts where air is escaping – use long tool like coat hanger wire etc.. to remove anything obstructing airflow carefully without damaging interior walls (as doing so could cause further damage).

Brush Roll not Spinning Properly

If you notice that your brush roll isn’t spinning properly, this may be causing weak suction power.as well as failing to agitate carpet fibres fully:

Solution: We advise cutting away entangled fibers wrapped around Brush roll. These fiber wraps are usually formed due certain types of fabric material clothing /bed linen tearing easily producing unravelling strands..

Bag Full Indicator Not Resetting

If your bag full indicator won’t reset even after changing the filter bag this indicates a blockage somewhere else within system :

Solution : open top cover which includes Bag Full Indicator(Button) by flipping upwards – press button underneath indicating device until it clicks back downward.To avoid future occurrence – empty dustbin frequently before reaching capacity .

Broken Belt or Misaligned Brush Roll

A broken belt or misaligned brush roll is another reason why suction may weaken.
NB Replace belt every year,and examine bristles on brushroll periodically-Look for wear/thinning edges.

Solution: Carefully remove base plate beneath vacuums bottom surface using screw driver/coin .

Check if roller spins freely giving smooth rotation motion; make sure sharpened/grooved edge faces downward when replacing aforementioned components.

Refer to manufacturer’s diagrams/manual instructions upon replacement.

Damaged Fan Blades in the Motor

Fan blades are integral part of motor unit hence any damages incurred will reduce efficiency at optimal level as required; this happens most often when debris enters motor Housing via inlet channels causing obstruction .

Solution: If you suspect fan blade damage,contact Riccar customer service center to arrange for repair services or replacement parts.

Defective Motor

The last and most serious possibility is that the motor itself may be faulty. In rare cases, only professional technicians can determine whether this is the cause of your suction issue.

Solution : Should none of above solutions solve problem there chance your machines motor needs servicing by a qualified technician.

Troubleshooting Tips for Riccar Vacuum No Suction

1. Clean or Replace Filters:

Checking/cleaning air, exhaust and motor filters on regular basis ensures optimal functioning.

Dirty filters will clog machine resulting in low suction pressure hence reducing overall performance; replace as needed depending upon frequency/type usage.


2. Remove Hose Blockage:

Detach both ends of vacuums hose.

Firstly inspect for possible cracks/damage with light shining at entrance /exit points.

If clean,your hose need clearing.

Use long tool [e.g.,a wire coat hanger] & insert end into hose (be sure not to push debris further inside)- Repeat until no visible signs remain trapped within system..

3. Repair/Replace Damaged Hose:

Once crack/holes has been found, repair temporarily using either duct tape/electrical tape but we strongly advise purchasing new part our contact certified technician.

4. Examine Brush Roll:

Brush rolls frequently accumulate dust/debris along edges which hinder spinning performance thus effecting its suction power.

It’s important comb out any tangles carefully cutting away fibres before re-assembly.

5. Check Bag Full Indicator:

If full indicator remains lit even after replacing empty filter bag, it means likely catridge located behind it has become blocked – simply remove from vacuum cleaning container using manual instruction given..press button till reset then securely insert back into device housing..

6. Align Belt & Brushroll

Check belt/belts according manufacturer instructions often ensuring secure fit.

Also ensure brushroll rotates smoothly with no excess noise or vibration.

7. Replace/Oil Fan Blades:

Use lubricant spray recommended by manufacturer in maintenance manual as excessive noise/vibrations emitted could indicate damage to components inside motor housing parts that warrant replacement part services via technician.

8.Call Professional Repair Service:

If none of the above troubleshooting steps solve your suction problem,contact Riccar customer service center directly for an appointment with qualified repair technician.

Author

  • Kevin L. Morris

    Hey there, I’m Kevin, from Colorado! I have been passionate about repairing appliances and electronics for the past 18 years. Modern vacuum cleaners break or malfunction way too often, so I have decided to contribute to vacuupedia.net and help my online readers with anything related to vacuums repair. I can’t wait to help you get your vacuum cleaner working again!

    View all posts